ACB thiab MCCB
Cov ntsiab lus
GPU1/2/3 Series ntse universal cua Circuit Court breaker yog tsim los tsim cov khoom lag luam los ntawm peb, ntsuas qhov hluav taws xob ntawm AC 50/60Hz, 480V (690V), ntsuas tam sim no 200A ~ 6300A, feem ntau siv rau kev faib hluav taws xob thiab kev tiv thaiv circuits rau hluav taws xob faib network, tiv thaiv cov khoom siv hluav taws xob thiab cov khoom siv hluav taws xob puas tsuaj los ntawm kev ua txhaum ntawm kev ua haujlwm ntau dhau, luv luv, kev ua txhaum hauv ntiaj teb, thiab lwm yam..Breaker kuj muaj kev cais tawm, nws ua raws li tus qauv ntawm GB 14048.2, IEC 60947-2
Nta
1. Compact qauv
2. Tsis muaj flashover nrug Kev nyab xeeb siab
3. Muaj peev xwm ntawm On-Off
4. Ntse hom kev tiv thaiv kev mus ncig tam sim no, nrog kev sib txuas lus sib txuas, tuaj yeem tswj tau los ntawm lub koos pij tawj pawg, paub txog tej thaj chaw deb ua haujlwm.
5. Zaub muaj nuj nqi ntawm ammeter, voltmeter
6. Kev nce thiab nqis tuaj yuav tsis cuam tshuam cov khoom lag luam
Qauv
GPU 3 | Universal cua Circuit Court breaker |
1600 | Shield ncej tam sim no |
4 | 3 3-theem tsis cim 4 4- Phase |
3M hom ntse maub los | Ntse tswj 2M hom: Digital tube zaub, khawm kho, 3 seem nrog earthing txhaum tiv thaiv muaj nuj nqi 3M hom: LCD zaub, khawm kho, 3 seem nrog earthing txhaum tiv thaiv muaj nuj nqi 3H hom: LCD zaub, khawm kho thiab kev sib txuas lus, 3 ntu nrog earthing txhaum tiv thaiv muaj nuj nqi. |
Mounting txoj kev | Hom kev kos tawm Tsau hom |
Txuas txoj kev | Kab rov tav kab ntsug kab rov tav Plate-rov qab cov kab hluav taws xob |
Accessories xaiv | Under-voltage tripper Mechanical interlock: 2 teeb los yog 3 teeb tawg hauv ntsug qib interlocked 2 teev breaker kab rov tav lossis ntsug interlocked los ntawm steel cable "Qhib" xauv txoj hauj lwm (tus yuam sij xauv) Draw-out 3 txoj hauj lwm hloov Sab nraud txuas N theem transformer |
Ib = 630 | Rated tam sim no (A) |
Nco tseg:
1. Ntse tswj yog M hom;Pab hloov pauv: 4 pawg 'kev sib cuag, txoj kev sib txuas yog nyob rau hauv kab rov tav.
2. Cov maub los ntse, shunt tso tawm, kaw electromagnetic, lub cev muaj zog tsav mechanism thiab under-voltage tripper yuav tsum tau teev tus nqi voltage thaum xaj.
Kev Xaiv Table
Hom | Rated ua hauj lwm voltage Ue (V) | Rated insulating voltage Ui (V) | Rated impulse withstand voltage Uimp (V) | Cov ntaub thaiv npog Tam sim no Inm (A) | Rated tam sim no Inm (A) | Phase naj npawb |
GPU 1-1250 | AC400 AC690 | AC 690, AC 1000 | 12000 | 1250 | 200, 400,630, 800,1000, 1250 | 3, 4 |
GPU 1-2000 | 2000 | 630, 800, 1000, 1250, 1600, 2000 | ||||
GPU 1-3200 | 3200 | 2000, 2500, 3600, 4000 | ||||
GPU 1-6300 | 6300 ib | 4000, 5000, 6300 |
Luv-circuit breaking peev xwm | Rated luv-lub sij hawm tiv taus tam sim no Icw (kA) / 1s | Kev ua haujlwm zoo | |||||
Rated max luv-circuit breaking peev Icu (kA) | Rated khiav luv-circuit breaking peev Ics (kA) | Mechanical life (lub sij hawm) | Hluav taws xob lub neej (lub sijhawm) | ||||
400 V | 690v ua | 400 V | 690v ua | 400 V | 690v ua | ||
50 | 42 | 42 | 15000 | 6000 | |||
80 | 50 | 50 | 40 | 50 | 40 | 15000 | 10000 |
100 | 65 | 80 | 50 | 80 | 50 | 12000 | 8000 (5000) |
120 | 75 | 100 | 65 | 100 | 65 | 3000 | 1000 |
GPM11 Moulded Case Circuit Breaker
GPM11Z Ntse Moulded Case Circuit Breaker
Cov ntsiab lus ntawm GPM11 / GPM11Z
GPM11 series molded case Circuit Breaker yog tsim rau AC 50 / 60Hz nyob ua haujlwm voltage 400V / 630V, ntsuas tam sim no mus txog 800A ntawm lub zog xa hluav taws xob rau kev faib hluav taws xob thiab kev tiv thaiv circuits, cov khoom siv hluav taws xob thiab cov khoom siv hluav taws xob tiv thaiv overload, under-voltage thiab luv luv Circuit Court txaus ntshai, nws txhim kho kev ntseeg siab ntawm lub hwj chim mov nyob rau hauv ib txwm siv tej yam kev mob uas tsis nquag pib li infrequent kab hloov dua siab tshiab thiab lub cev muaj zog.Thiab nrog kev sib cais ua haujlwm ib yam nkaus.Nws ua tau raws li tus qauv ntawm GB / T 14048.2 thiab IEC 60947-2.
Qauv
GPM11GPM11Z | Moulded Case Circuit BreakerSmart Moulded Case Circuit Breaker |
100 | Shield ncej tam sim no |
H | Short-circuit breaking peev: N: Hom S: Standard typeH: High-breaking type |
P | Kev khiav hauj lwm txoj kev: Motorized kev khiav hauj lwm: PROtate kov khiav hauj lwm: ZDirect lag luam (tsis muaj code) |
2 | Kev tiv thaiv feature Xaiv: kev tiv thaiv kev faib tawm: tsis muaj codeMotor tiv thaiv: 2 |
4 | Theem 2: ob theem 3: peb theem4 :ua 4fas |
208 | Txoj kev mus ncig thiab cov khoom siv sab hauv |
Ib = 100 | Rated tam sim no (A) |
B | 4 Phase breaker N theem muaj 4 ntau hom cim raws li A, B, C, DA: N theem yuav tsis nruab tripper tam sim no, thiab N txuas ib txwm, tsis ua haujlwm nrog lwm 3 theem.B: N theem tsis nruab tripper tam sim no, thiab N theem tsis ua haujlwm nrog lwm 3 theem.C: N theem tau teeb tsa tam sim no tripper, thiab N theem ua haujlwm nrog lwm 3 theem.D: N theem teeb tsa tam sim no tripper, thiab N theem txuas nrog ib txwm, Tsis ua haujlwm nrog lwm 3 theem. |
Q | Txoj kev xaim: Pem hauv ntej ntawm phaj thaiv: QRear ntawm phaj thaiv: HPlug-in hom thaiv: R |
Lus Cim: 1. Txoj kev xaim: nram qab ntawm cov phaj thaiv (400, 630's 4P tsis muaj nws);plug-in hom thaiv (4P tsis muaj nws)
2. Cov khoom siv sab hauv yog ntsia rau sab laug ntawm lub breaker.
Kev xaiv lub rooj rau GPM11Z MCCB
Hom | Rated ua hauj lwm voltage Ue (V) | Rated insulating voltage Ui (V) | Rated impulse tiv taus voltage Uimp (V) | Cov ntaub thaiv npog Tam sim no Inm (A) | Rated tam sim no Inm (A) | Phase naj npawb | Luv-circuit breaking peev xwm | Rated luv-lub sij hawm tiv taus tam sim no Icw (kA) 1s | Kev ua haujlwm zoo | ||
Rated max luv-circuit breaking peev Icu (kA) | Rated khiav luv-circuit breaking peev Ics (kA) | Mechanical life (lub sij hawm) | Hluav taws xob lub neej (lub sij hawm) | ||||||||
GPM11Z-100 | TSI AC400 | SIB 690 | TSI 8000 | 100 | 32, 100 ib | 3,4 ib | 65 | 50 | 1 | 20000 | 8000 |
GPM11Z-225 | 225 | 225 | 65 | 50 | 2.5 | 20000 | 8000 | ||||
GPM11Z-400 | 400 | 400 | 65 | 50 | 5 | 15000 | 7000 | ||||
GPM11Z-630 | 630 | 630 | 65 | 50 | 8 | 10000 | 7000 |
Kev xaiv lub rooj rau GPM11 MCCB
Hom | Rated ua hauj lwm voltage Ue | Rated insulating voltage Ui | Rated impulse withstand voltage Uimp | Ncej chav kawm ntsuas tam sim no Inm A | Rated tam sim no hauv (A) | Phase naj npawb | Rated max luv-circuit tawg peev xwm code | Rated max luv - Circuit Court breaking peev xwm | Rated khiav luv-circuit breaking peev Ics (kA) | Trip ntaus ntawv hom | Kev ua haujlwm siab (lub sijhawm) | |
Nyob | Tsis Nyob | |||||||||||
PIB 11-63 | 400, 690 Ib | 800, 1000 Nws | 8 | 63 | 10, 16, 20, 25, 32, 40, ib. 50, 63 ib | 3 | N | 10 | 5 | Thaum tshav kub kub electromagnetic | 3000 | 7000 |
3,4 ib | S | 25 | 18 | Thaum tshav kub kub electromagnetic | ||||||||
3,4 ib | H | 50 | 35 | Thaum tshav kub kub electromagnetic | ||||||||
GPM11-100 | 100 | 16, 20, 25, ib. 32, 40, 50, ib. 63, 80, 100 ib | 3 | N | 35 | 25 | Thaum tshav kub kub electromagnetic | 3000 | 7000 | |||
3,4 ib | S | 50 | 35 | Thaum tshav kub kub electromagnetic | ||||||||
3,4 ib | H | 65 | 50 | Thaum tshav kub kub electromagnetic | ||||||||
GPM11-160 | 160 | 100, 125, 140, 160 ib | 3 | N | 35 | 25 | Thaum tshav kub kub electromagnetic | 1500 | 6500 ib | |||
3,4 ib | S | 50 | 35 | Thaum tshav kub kub electromagnetic | ||||||||
3,4 ib | H | 65 | 50 | Thaum tshav kub kub electromagnetic | ||||||||
PIB 11-225 | 225 | 100, 125, 140, 160, ib. 180, 200, ib. 225 | 3 | N | 35 | 25 | Thaum tshav kub kub electromagnetic | 1500 | 6500 ib | |||
3,4 ib | S | 50 | 35 | Thaum tshav kub kub electromagnetic | ||||||||
3,4 ib | H | 65 | 50 | Thaum tshav kub kub electromagnetic | ||||||||
PIB 11-250 | 250 | 100, 125, 140, 160, ib. 180, 200, ib. 225, 250 ib | 3 | N | 35 | 25 | Thaum tshav kub kub electromagnetic | 1500 | 6500 ib | |||
3,4 ib | S | 50 | 35 | Thaum tshav kub kub electromagnetic | ||||||||
3,4 ib | H | 65 | 50 | Thaum tshav kub kub electromagnetic | ||||||||
PIB 11-400 | 400 | 225, 250, ib. 315, 350, ib. 400 | 3 | N | 35 | 25 | Thaum tshav kub kub electromagnetic | 1000 | 4000 | |||
3,4 ib | S | 50 | 35 | Thaum tshav kub kub electromagnetic | ||||||||
3,4 ib | H | 65 | 50 | Thaum tshav kub kub electromagnetic | ||||||||
PIB 11-630 | 630 | 400, 500, 630, 630, ib. 700, 800 ib | 3 | N | 35 | 25 | Thaum tshav kub kub electromagnetic | 1000 | 4000 | |||
3,4 ib | S | 50 | 35 | Thaum tshav kub kub electromagnetic | ||||||||
3,4 ib | H | 65 | 50 | Thaum tshav kub kub electromagnetic | ||||||||
PIB 11-800 | 800 | 630, 700 ib. 800 | 3,4 ib | S | 50 | 35 | Thaum tshav kub kub electromagnetic | 1000 | 4000 | |||
3,4 ib | H | 65 | 50 | Thaum tshav kub kub electromagnetic |