Indicators Thiab Zog Meter
Hom lus piav qhia
Hom | Yam khoom | Cov txheej txheem pom | Hwj chim | Xauv ib leeg | Xauv ob qhov kev sib cuag | Ntxig | Tus kheej | Dimension | Txiav loj | Daim duab | |
kuaj | tiv tauj | kuaj | |||||||||
Builtin hom | GPXN-Q | Key-nias | - | 96 × 48 × 88 | 91 × 44 | 3 | |||||
GPXN-T | Key-nias | 96 × 48 × 55 | 91 × 44 | 3 | |||||||
Swg. | GPXN1-Q | Brightness | - | - | 96 × 48 × 88 | 91 × 44 | 1 | ||||
GPXN1-T | Brightness | - | 96 × 48 × 55 | 91 × 44 | 1 | ||||||
GPXN4-Q | Key-nias | - | - | 144 × 48 × 104 hli | 138 × 44 | 4 | |||||
GPXN4-T | Key-nias | - | 144 × 48 × 104 hli | 138 × 44 | 4 | ||||||
GPXN5-Q | Key-nias | - | - | 96 × 48 × 88 | 91 × 44 | 2 | |||||
GPXN5-T | Key-nias | - | 96 × 48 × 55 | 91 × 44 | 2 | ||||||
Ib Insulator nrog 2 Indicators | GPXN4-Q/M | Key-nias | - | - | 144 × 48 × 104 hli | 138 × 44 | 4 | ||||
GPXN4-T/M | Key-nias | - | 144 × 48 × 104 hli | 138 × 44 | 4 | ||||||
GPXN4-T/Z | Key-nias | 144 × 48 × 104 hli | 138 × 44 | 4 | |||||||
Hom tshwj xeeb | GPXN1-Q/CS | Brightness | - | - | - | 96 × 48 × 88 | 91 × 44 | ||||
GPXNP1-Q/W | Brightness | - | - | - | 96 × 48 × 88 | 91 × 44 | 1 | ||||
GPXN-Q/LCS | Brightness | - | - | 96 × 48 × 88 | 91 × 44 | 3 |
Voltage Indicator Siv nyob rau hauv lub nplhaib Main Unit
Lub ntsuas hluav taws xob yog siv ua ke nrog insulator los qhia txog lub xeev hluav taws xob ntawm qhov hluav taws xob hluav taws xob.
Lub ntsuas hluav taws xob txuas ntxiv GPXN9-C yog siv nrog qhov taw qhia los qhia lub xeev hluav taws xob.Qhov deb ntawm lub hwj chim-check davhlau ya nyob twg yog 14mm lossis 19mm.
Phase comparator GPXN-C yog siv nrog qhov taw qhia los qhia txog lub xeev hluav taws xob ntawm high-voltage circuitry thiab xyuas cov theem ua ntu zus ntawm cov khoom siv hluav taws xob.
Kev kuaj xyuas fais fab: theem sib piv tso rau hauv lub ntiaj teb lossis lwm qhov chaw ntawm cov khoom siv hluav taws xob siab.
Phase-check: theem sib piv tso rau hauv tib theem hluav taws xob-check davhlau ya nyob twg ntawm ob lub high-voltage khoom, yog tias lub teeb ci LED yog ci, nws qhia tau hais tias qhov ntsuas theem muaj lub zog.
Qhov taw qhia txoj hauj lwm
Qhov taw qhia txoj haujlwm tuaj yeem simulate txoj haujlwm ua haujlwm thiab cov xwm txheej ntawm cov cuab yeej hloov pauv xws li hloov thiab Circuit Court breaker hauv hluav taws xob.Nws yog dav siv nyob rau hauv txhua yam ntawm mimic board ntawm central tswj chav tsev thiab vaj huam sib luag ntawm switchgear nyob rau hauv lub hwj chim cog, lub hwj chim chaw nres tsheb thiab transformer chaw nres tsheb.Qhov serial ntawm txoj haujlwm ntsuas no muaj kev ntseeg siab, ntau yam ntawm kev ua haujlwm voltage thiab ntev lifespan.DC thiab AC muaj rau kev siv.
Technical Parameters
Rated voltage | DC / AC 98V ~ 242V |
Luminous siv | 40 cd / ㎡ |
Fais fab zaus withstand voltage | 2 kV / 1 min |
Rwb thaiv tsev tsis kam | ≥100MΩ |
Lub zog dissipation | ≤1W |
Ua haujlwm kub | -15 ℃ to + 50 ℃ |
Lub neej ntev | > 10 xyoo |
Zaub muaj nuj nqi | Kev ua haujlwm yog qhia nrog xim liab / ntsuab thiab cov duab (Raws li cov neeg siv khoom xaiv) |
Daim ntawv Dimension: | 37.5 × 37.5 × 62 hli |
Txiav loj: | Φ25 (mm) |
Qauv | Kev piav qhia |
GPWZ25-K/2 | Position Indicator-Circuit-Breaker |
GPWZ25-E/1 | Position Indicator-Earthing Switch |
GPWZ25-B/2 | Position Indicator-Tau Truck |
GPWZ25-B/1 | Position Indicator-Disconnector |
GPWZ25-K/1 | Position indicator-Peb txoj hauj lwm Hloov |
Txoj hauj lwm qhia qhov screen GPAS-72
GPAS-72 serial txoj hauj lwm qhia lub vijtsam txais LED ua lub teeb ci, nrog kev siv hluav taws xob tsawg, kev ntseeg siab, kev pab lub neej ntev, thiab lwm yam.Nrog rau ntau lub zog ntawm theem-voltage taw qhia, kev cuam tshuam, ntsuas kub & av noo, kev taw qhia lub tsheb kauj vab, kev taw qhia txog kev hloov hluav taws xob, lub ntiaj teb hloov cov xwm txheej, qhia lub zog.Nws yog qhov kev xaiv zoo los hloov qhov ib txwm hloov pauv lub xeev txoj haujlwm qhia.
Technical Parameters
Rated voltage | AC / DC 110V / 220V Lub cev muaj zog |
Fais fab zaus tiv taus | 2 kV / min |
Ib puag ncig ua haujlwm | -25 ℃ to 55 ℃, ≤ 90% RH |
Analog teeb pom kev zoo luminance | > 40cd/m2 |
Lub neej ua haujlwm | 10 xyoo |
Kev tiv thaiv qib | IP42 |
Dimension | 199 x 146 x 63 mm |
Txiav loj | 177 x 121 mm |
Technical ParametersGpj-3100 Series Short Circuit Thiab Earth Fault Indicator
Lub GPJ-3100 series ntawm luv luv Circuit Court thiab lub ntiaj teb txhaum qhov taw qhia yog tsim los rau kev sim thiab qhia luv luv Circuit Court thiab lub ntiaj teb txhaum nyob rau hauv lub sij hawm.Nws yog siv los saib xyuas circuitry nyob rau hauv RMU, overhead kab, fais fab cable faib kab, box-hom transformer thiab lwm qhov chaw zoo sib xws.Raws li lub tswb ceeb toom qhia los ntawm qhov taw qhia, cov neeg ua haujlwm tuaj yeem txiav txim siab thiab txiav qhov chaw txhaum sai sai thaum lub sijhawm luv luv lossis lub ntiaj teb txhaum tshwm sim hauv Circuit Court, yog li lub kaw lus tuaj yeem rov qab muab lub zog rau qhov tsis muaj qhov txhaum tam sim ntawd kom txuag sijhawm thiab txhim kho kev ua haujlwm.
Technical Data
1. Short circuit alarming tam sim no: 100A txog 1000A lub sij hawm ncua 40ms
2. Earthing alarming tam sim no: 20A, 30A, 40A, 50A, 60A ± 10% ncua sij hawm 40ms
3. Qhov kub thiab txias: -25 txog +70 ℃
4. Cov av noo: ≦95%
5. Lub ntiaj teb txhuas ntev: 4m
6. Coj qhov muag fiber ntau ntev 3.5m
7. Fais fab mov: lithium roj teeb 3.6V / 2.45Ah
8. Nws pib dua lub sijhawm: 7s, 2hrs, 4hrs, 8hrs
9. Cov zis hluav taws xob: 120V AC 1A, 30V DC 2A
10.Main controller dimension: 95x50x80mm
11. Txiav qhov loj: 91x44 mm
12.Protection class: Main Controller: IP40, Sensor: IP65