Cov qauv, lub hauv paus ntsiab lus thiab cov yam ntxwv ntawm lub tshuab nqus tsev Circuit Court breaker
Cov qauv ntawm lub tshuab nqus tsev Circuit Court breaker
Cov qauv ntawm lub tshuab nqus tsev Circuit Court breaker yog tsim los ntawm peb qhov chaw: lub tshuab nqus tsev arc extinguishing chamber, kev khiav hauj lwm mechanism, kev txhawb nqa thiab lwm yam khoom.
1. Lub tshuab nqus tsev cuam tshuam
Nqus interrupter, tseem hu ua lub tshuab nqus tsev hloov raj, yog lub hauv paus tseem ceeb ntawm lub tshuab nqus tsev vacuum.Nws lub luag haujlwm tseem ceeb yog ua kom muaj qhov nruab nrab thiab qhov hluav taws xob siab hluav taws xob kom tua hluav taws sai sai thiab cuam tshuam qhov tam sim no tom qab txiav tawm lub zog hluav taws xob los ntawm kev ua haujlwm zoo ntawm rwb thaiv tsev ntawm lub tshuab nqus tsev hauv cov yeeb nkab, kom tsis txhob muaj kev sib tsoo thiab kev sib tsoo.Nqus interrupters tau muab faib ua iav nqus interrupters thiab ceramic nqus interrupters raws li lawv lub plhaub.
Nqus arc extinguishing chamber yog tsim los ntawm huab cua nruj insulating plhaub, conductive circuit, shielding system, tiv tauj, bellows thiab lwm yam.
1) Cua nruj rwb thaiv tsev system
Cov cua nruj rwb thaiv tsev txheej txheem muaj cov cua nruj rwb thaiv tsev plhaub ua los ntawm iav los yog ceramics, ib tug txav kawg cover phaj, ib tug ruaj kawg cover phaj, thiab ib tug stainless steel bellows.Txhawm rau kom muaj huab cua nruj zoo ntawm iav, ceramics thiab hlau, ntxiv rau cov txheej txheem kev ua haujlwm nruj thaum lub sijhawm sib khi, qhov permeability ntawm cov khoom nws tus kheej yuav tsum ua kom tsawg li tsawg tau thiab cov cua tso tawm sab hauv yog txwv rau qhov tsawg kawg nkaus.Stainless hlau bellows tuaj yeem tsis tsuas yog cais lub tshuab nqus tsev hauv lub tshuab nqus tsev arc extinguishing chamber los ntawm lub xeev atmospheric sab nraud, tab sis kuj ua rau kev txav mus los thiab cov pas nrig txav txav txav mus rau hauv qhov tau teev tseg kom ua tiav kev sib txuas thiab kev ua haujlwm ntawm lub tshuab nqus tsev.
2) Conductive system
Lub kaw lus ntawm lub arc extinguishing chamber muaj cov kav hlau txuas ruaj khov, qhov ruaj khov khiav arc nto, kev sib cuag ruaj khov, kev sib cuag, kev txav khiav arc nto thiab cov pas nrig txav.Ntawm lawv, tus pas ntsuas hluav taws xob ruaj khov, qhov ruaj khov khiav arc nto thiab kev sib cuag ruaj khov yog sib sau ua ke hu ua cov electrode ruaj khov;Tsiv kev sib cuag, txav arc nto thiab txav conductive pas nrig yog sib sau ua ke hu ua txav electrode.Thaum lub tshuab nqus tsev vacuum breaker, lub tshuab nqus tsev hloov pauv thiab lub tshuab nqus tsev contactor sib sau ua ke los ntawm lub tshuab nqus tsev arc extinguishing chamber raug kaw, lub tshuab ua haujlwm kaw ob qhov kev sib cuag los ntawm kev txav ntawm cov pas nrig txav, ua tiav kev sib txuas ntawm lub voj voog.Txhawm rau kom muaj kev sib cuag ntawm ob qhov kev sib cuag me me raws li qhov ua tau thiab ruaj khov, thiab muaj lub zog zoo txhua yam thaum lub arc extinguishing chamber bears lub dynamic ruaj khov tam sim no, lub tshuab nqus tsev hloov yog nruab nrog lub tes tsho qhia ntawm ib qho kawg ntawm dynamic conductive. pas nrig, thiab ib txheej ntawm compression springs yog siv los tuav lub ntsuas siab ntawm ob qhov kev sib cuag.Thaum lub tshuab nqus tsev hloov pauv tam sim no, ob qhov kev sib cuag ntawm arc extinguishing chamber cais thiab tsim ib qho arc nruab nrab ntawm lawv kom txog rau thaum lub arc tawm mus thaum tam sim no ib txwm hla xoom, thiab lub Circuit Court breaking tiav.
3) Kev tiv thaiv system
Lub shielding system ntawm lub tshuab nqus tsev arc extinguishing chamber yog tsim los ntawm shielding lub tog raj kheej, shielding cover thiab lwm yam.Lub luag haujlwm tseem ceeb ntawm lub shielding system yog:
(1) Tiv thaiv kom tsis txhob muaj kev sib cuag los ntawm kev tsim cov hlau vapor ntau thiab cov kua dej ntws tawm thaum lub sij hawm arcing, polluting lub puab phab ntsa ntawm insulating plhaub, ua rau lub rwb thaiv tsev lub zog poob los yog flashover.
(2) Kev txhim kho cov hluav taws xob hauv hluav taws xob hauv lub tshuab nqus tsev cuam tshuam yog qhov tsim nyog rau qhov miniaturization ntawm lub plhaub rwb thaiv tsev ntawm lub tshuab nqus tsev cuam tshuam, tshwj xeeb tshaj yog rau miniaturization ntawm lub tshuab nqus tsev interrupter nrog high voltage.
(3) Absorb ib feem ntawm arc zog thiab condense arc khoom.Tshwj xeeb tshaj yog thaum lub tshuab nqus tsev cuam tshuam cuam tshuam qhov luv-circuit tam sim no, feem ntau ntawm cov hluav taws xob hluav taws xob uas tsim los ntawm arc yog absorbed los ntawm cov ntaub thaiv npog, uas yog qhov tsim nyog rau kev txhim kho lub zog dielectric rov qab ntawm cov neeg sib cuag.Qhov ntau dua cov khoom arc absorbed los ntawm lub shielding system, lub zog ntau dua nws absorbs, uas plays lub luag hauj lwm zoo nyob rau hauv kev ua kom lub peev xwm ntawm lub tshuab nqus tsev interrupter.
4) Tiv tauj system
Kev sib cuag yog qhov chaw uas lub arc yog tsim thiab tua, thiab cov kev xav tau ntawm cov khoom siv thiab cov qauv yog qhov siab.
(1) Cov ntaub ntawv tiv tauj
Muaj cov cai hauv qab no rau cov ntaub ntawv tiv tauj:
ib.Muaj peev xwm tawg
Nws yuav tsum tau hais tias lub conductivity ntawm cov khoom nws tus kheej yog loj, lub thermal conductivity coefficient yog me me, lub thermal muaj peev xwm loj, thiab lub thermal electron emission muaj peev xwm yog tsawg.
b.High breakdown voltage
High breakdown voltage ua rau siab dielectric rov muaj zog, uas yog zoo rau arc extinguishing.
c.High hluav taws xob corrosion kuj
Ntawd yog, nws tuaj yeem tiv taus qhov ablation ntawm hluav taws xob arc thiab muaj hlau evaporation tsawg dua.
d.Resistance rau fusion vuam.
e.Tus nqi qis qis tam sim no yuav tsum tau qis dua 2.5A.
f.Cov ntsiab lus roj tsawg
Cov ntsiab lus tsis tshua muaj cua yog qhov yuav tsum tau rau txhua yam khoom siv hauv lub tshuab nqus tsev cuam tshuam.Tooj liab, tshwj xeeb, yuav tsum yog cov tooj liab tsis muaj oxygen uas tau kho los ntawm cov txheej txheem tshwj xeeb nrog cov ntsiab lus roj tsawg.Thiab cov alloy ntawm cov nyiaj thiab tooj liab yog xav tau rau solder.
g.Cov khoom sib txuas ntawm lub tshuab nqus tsev arc extinguishing chamber rau Circuit Court breaker feem ntau yog siv tooj liab chromium alloy, nrog tooj liab thiab chromium accounting rau 50% feem.Ib daim ntawv tooj liab chromium alloy nrog lub thickness ntawm 3 hli yog welded rau ntawm qhov chaw mating ntawm sab sauv thiab qis sib cuag.Tus so yog hu ua hu rau puag, uas tuaj yeem ua los ntawm oxygen dawb tooj liab.
(2) Cov qauv kev sib cuag
Cov qauv kev sib cuag muaj qhov cuam tshuam zoo rau lub peev xwm tawg ntawm arc extinguishing chamber.Lub arc extinguishing nyhuv tsim los ntawm kev siv kev sib cuag nrog cov qauv sib txawv.Muaj peb hom kev sib cuag: kauv trough hom qauv kev sib cuag, khob-zoo li tus qauv hu nrog chute thiab khob-zoo li tus qauv kev sib cuag nrog longitudinal magnetic teb, uas lub khob-zoo li tus qauv hu nrog longitudinal magnetic teb yog lub ntsiab.
5) Poob
Lub tshuab nqus tsev vacuum arc extinguishing chamber yog lub luag haujlwm tseem ceeb rau kev ua kom lub zog ntawm cov electrode txav nyob rau hauv ib qho chaw thiab tswj lub tshuab nqus tsev kom ntev, thiab siv los xyuas kom meej tias lub tshuab nqus tsev arc extinguishing chamber muaj lub neej txhua yam.Lub tshuab nqus tsev vacuum interrupter yog nyias-walled khoom ua los ntawm stainless hlau nrog ib tug tuab ntawm 0.1 ~ 0.2 hli.Thaum lub sij hawm qhib thiab kaw ntawm lub tshuab nqus tsev hloov, lub hauv paus ntawm lub arc extinguishing chamber yuav tsum tau nthuav thiab contraction, thiab seem ntawm lub tshuab nqus tsev vacuum yog hloov pauv, yog li lub neej kev pab cuam ntawm lub tshuab nqus tsev twj yuav tsum tau txiav txim siab raws li qhov chaw ntawm lub tshuab nqus tsev vacuum. rov nthuav dav thiab contraction thiab kev pabcuam siab.Lub neej kev pab cuam ntawm lub tshuab nqus tsev yog cuam tshuam nrog cov cua kub ntawm qhov chaw ua haujlwm.Tom qab lub tshuab nqus tsev arc extinguishing chamber tsoo lub luv luv-circuit tam sim no, cov seem cua sov ntawm cov pas nrig conductive raug xa mus rau hauv lub tshuab kom nce qhov kub ntawm lub tshuab nqus tsev.Thaum qhov kub nce mus rau ib qho twg, nws yuav ua rau qaug zog ntawm lub tshuab nqus tsev thiab cuam tshuam rau lub neej kev pab cuam ntawm lub tshuab raj.
Lub sij hawm xa tuaj: Plaub Hlis-04-2022